Industrial UPS 80-250K
80kVA-250kVA Three Phase Online Industrial Low Frequency UPS
Industrial Online UPS with Isolation Transformer
LBT Power UPS adopts advanced Digital Signal Processing(DSP) and robust Transformer-based online double-conversion technology, whichprovides superior isolation and exceptional reliability for harsh environments.The system is engineered for heavy-duty performance, high overload capacity,and maximum stability, featuring a built-in output isolation transformer toeffectively block grid interference and harmonic noise.
Including high-performance rectifiers, heavy-dutyinverters, static bypass switches, and manual maintenance bypasses, it deliversa pure, galvanically isolated power supply for the most demanding loads.Whether facing extreme grid fluctuations or inductive motor loads, it ensuresuncompromised safety and continuous power protection for industrial automation,medical facilities, and large-scale data centers.
Performance:
• Real online UPS,pure sine wave output, the application of dual conversion pure online IGBTtechnology, small volume, low noise, durable.
• LCD displaypanel, through the LCD selection switch, convenient to check the UPS workingstate: whether the battery is normal, input / output voltage value, input /output frequency value, battery voltage value, output power and other importantparameters.
• The inputvoltage is particularly wide, allowing 25% of the change can be full load work,reduce the opportunity of battery discharge, effectively extend the life.
• The chargingcurrent is 1~10A adjustable, which meets the charging requirements of thelong-time power supply system, especially designed for China's power grid.
• Special staticswitch design, with zero output interruption during power grid failure, and abypass output time of<2 ms during UPS failure.
• Very strong loadcapacity, 125% load online work for 15 minutes, load more than 125% online workfor 60 seconds to bypass, load more than 150%3 seconds to bypass output,overload phenomenon disappeared after the automatic restart operation.
• Output shortcircuit protection to ensure that the UPS is not damaged by short circuit ofexternal load.
• Temperaturecontrol and protection, set the internal temperature, protection componentlife.
• Has a powerfulload start function, can be directly turned on in the battery state, supplyoutput.
• Input / outputis completely isolated, with strong anti-interference ability, strong impactresistance, safe and reliable.
• Provide adual-machine thermal backup power supply system.
• Unique soundalarm to remind the user to notice the working state of the UPS.
• Built-inmaintenance bypass, can achieve online maintenance.
• RS232communication interface, with optional remote monitoring function.

Rectifier technicalparameters
Nominal capacity(KVA)
10
15
20
30
40
50
60
80
100
120
160
200
250
300
400
500
600
Input maximum current
25
33
40
55
71
86
102
133
164
195
266
334
420
492
656
840
984
Working principle
On-line power supply, static bypass switch (uninterrupted switching), double conversion technology, complete isolation of output power
Phase number
Three phase + N
Nominal Voltage
380VAC±20%
Nominal frequency
50Hz±10%,60Hz±10%
Current harmonic distortion
<5%(12 pulses, option below 400K)
soft start
0~100% 5sec
Output voltage
432VDC
Recharging current
5-10A(adjustable)
5-20A(adjustable)
10A~30A(adjustable)
20A~60A(adjustable)
Battery
Nominal capacity(KVA)
10
15
20
30
40
50
60
80
100
120
160
200
250
300
400
500
600
Maximum discharge current(A)
28
42
56
85
113
141
169
225
282
338
451
564
705
846
1028
1285
1542
Quantity unit
12V*32 Knots Or 2V*192 Knots
Nominal battery voltage
384VDC
float voltage
432VDC
Discharge cut-off voltage
345VDC
Inverter
Standard capacity(KVA)
10
15
20
30
40
50
60
80
100
120
160
200
250
300
400
500
600
Rated power(KW)
COSΦ=0.8
8
12
16
24
32
40
48
64
80
96
128
160
200
240
320
400
480
Phase number
Three phase + N
Nominal Voltage
3/1:220VAC±1%;3/3:380VAC±1%
Nominal frequency
50Hz±0.5%,60Hz±0.5%(Battery powered)
Frequency Stability 1
<±0.5%(Battery mode)
Crest factor
3:1
Output waveform
Sine wave
Total harmonic distortion
Linear load<3%;Nonlinear load<5%
Dynamic load voltage
<±4%(Jump from 0 to 100%)
Instant recovery time
<10ms
Balanced load voltage
<±1%;<±5%(Unbalanced load voltage)
Overload capacity
125% 10min,150% 1min
Inverter efficiency
94
94
95
95
96
96
96
96
96
96
96
96
96
96
96
96
96
Bypass
Nominal capacity(KVA)
10
15
20
30
40
50
60
80
100
120
160
200
250
300
400
500
600
Phase number
Three phase + N
Nominal Voltage
380VAC±15%
Nominal frequency
50Hz±5%,60Hz±5%
Inverter/Bypass (transfer time)
0ms(Overload)
System
Model
10
15
20
30
40
50
60
80
100
120
160
200
250
300
400
500
600
Overall efficiency
>94%
Communication interface
Rs232/485,SNMP(Options)
Operating temperature
0~40℃
Relative temperature (non-condensing)
30%~95%
Running height
<1000 meters (power decreases by 1% for every additional 100 meters, up to 4000 meters)
Cooling method
forced ventilation
Noise(dB)
48~60
55
65
80
Box color
Left front door black, other ice gray (GY09)
Input cable
bottom/back
Maintenance surface
front/top/side
front/back
Dimensions
Width
(mm)
350
450
600
1000
1200
1400(6P)
Deep
(mm)
700
850
800
800
900
1000
High
(mm)
900
1230
1400
1680
1850
1900
Weight(KG)
177
208
215
277
290
310
350
510
570
720
820
960
1350
1450
1750
1950
2850
Input device
Terminal block
Output device
Terminal block