  • Industrial UPS 300-600K

    250kVA-300kVA Three Phase Online UPS   Industrial Low Frequency UPS

    Industrial Online UPS with Isolation Transformer

     

    LBT Power UPS adopts advanced Digital Signal Processing(DSP) and robust Transformer-based online double-conversion technology, whichprovides superior isolation and exceptional reliability for harsh environments.The system is engineered for heavy-duty performance, high overload capacity,and maximum stability, featuring a built-in output isolation transformer toeffectively block grid interference and harmonic noise.

    Including high-performance rectifiers, heavy-dutyinverters, static bypass switches, and manual maintenance bypasses, it deliversa pure, galvanically isolated power supply for the most demanding loads.Whether facing extreme grid fluctuations or inductive motor loads, it ensuresuncompromised safety and continuous power protection for industrial automation,medical facilities, and large-scale data centers.

     

    Performance:

    •   Real online UPS,pure sine wave output, the application of dual conversion pure online IGBTtechnology, small volume, low noise, durable.

    •   LCD displaypanel, through the LCD selection switch, convenient to check the UPS workingstate: whether the battery is normal, input / output voltage value, input /output frequency value, battery voltage value, output power and other importantparameters.

    •   The inputvoltage is particularly wide, allowing 25% of the change can be full load work,reduce the opportunity of battery discharge, effectively extend the life.

    •   The chargingcurrent is 1~10A adjustable, which meets the charging requirements of thelong-time power supply system, especially designed for China's power grid.

    •   Special staticswitch design, with zero output interruption during power grid failure, and abypass output time of<2 ms during UPS failure.

    •   Very strong loadcapacity, 125% load online work for 15 minutes, load more than 125% online workfor 60 seconds to bypass, load more than 150%3 seconds to bypass output,overload phenomenon disappeared after the automatic restart operation.

    •   Output shortcircuit protection to ensure that the UPS is not damaged by short circuit ofexternal load.

    •   Temperaturecontrol and protection, set the internal temperature, protection componentlife.

    •   Has a powerfulload start function, can be directly turned on in the battery state, supplyoutput.

    •   Input / outputis completely isolated, with strong anti-interference ability, strong impactresistance, safe and reliable.

    •   Provide adual-machine thermal backup power supply system.

    •   Unique soundalarm to remind the user to notice the working state of the UPS.

    •   Built-inmaintenance bypass, can achieve online maintenance.

    •   RS232communication interface, with optional remote monitoring function.

     

     

      

    Rectifier technicalparameters

    Nominal capacity(KVA)

    10

    15

    20

    30

    40

    50

    60

    80

    100

    120

    160

    200

    250

    300

    400

    500

    600

    Input maximum   current

    25

    33

    40

    55

    71

    86

    102

    133

    164

    195

    266

    334

    420

    492

    656

    840

    984

    Working principle

    On-line power   supply, static bypass switch (uninterrupted switching), double conversion   technology, complete isolation of output power

    Phase number

    Three phase + N

    Nominal Voltage

    380VAC±20%

    Nominal frequency

    50Hz±10%,60Hz±10%

    Current harmonic   distortion

    <5%(12 pulses, option below 400K)

    soft start

    0~100% 5sec

    Output voltage

    432VDC

    Recharging current

    5-10A(adjustable)

    5-20A(adjustable)

    10A~30A(adjustable)

    20A~60A(adjustable)

     

      

     

     

    Battery

    Nominal capacity(KVA)

    10

    15

    20

    30

    40

    50

    60

    80

    100

    120

    160

    200

    250

    300

    400

    500

    600

    Maximum discharge   current(A)

    28

    42

    56

    85

    113

    141

    169

    225

    282

    338

    451

    564

    705

    846

    1028

    1285

    1542

    Quantity unit

    12V*32 Knots Or   2V*192 Knots

    Nominal battery   voltage

    384VDC

    float voltage

    432VDC

    Discharge cut-off   voltage

    345VDC

     

    Inverter

    Standard capacity(KVA)

    10

    15

    20

    30

    40

    50

    60

    80

    100

    120

    160

    200

    250

    300

    400

    500

    600

    Rated power(KW)

    COSΦ=0.8

    8

    12

    16

    24

    32

    40

    48

    64

    80

    96

    128

    160

    200

    240

    320

    400

    480

    Phase number

    Three phase + N

    Nominal Voltage

    3/1:220VAC±1%;3/3:380VAC±1%

    Nominal frequency

    50Hz±0.5%,60Hz±0.5%(Battery   powered)

    Frequency Stability   1

    <±0.5%(Battery mode)

    Crest factor

    3:1

    Output waveform

    Sine wave

    Total harmonic   distortion

    Linear load<3%;Nonlinear load<5%

    Dynamic load voltage

    <±4%(Jump from 0 to 100%)

    Instant recovery   time

    <10ms

    Balanced load   voltage

    <±1%;<±5%(Unbalanced load voltage)

    Overload capacity

    125% 10min,150% 1min

    Inverter efficiency

    94

    94

    95

    95

    96

    96

    96

    96

    96

    96

    96

    96

    96

    96

    96

    96

    96

     

     

     

     

    Bypass

    Nominal capacity(KVA)

    10

    15

    20

    30

    40

    50

    60

    80

    100

    120

    160

    200

    250

    300

    400

    500

    600

    Phase number

    Three phase + N

    Nominal Voltage

    380VAC±15%

    Nominal frequency

    50Hz±5%,60Hz±5%

    Inverter/Bypass   (transfer time)

    0ms(Overload)

     

     

     

    System

    Model 

    10

    15

    20

    30

    40

    50

    60

    80

    100

    120

    160

    200

    250

    300

    400

    500

    600

    Overall efficiency

    >94%

    Communication   interface

    Rs232/485,SNMP(Options)

    Operating   temperature

    0~40℃

    Relative temperature   (non-condensing)

    30%~95%

    Running height

    <1000 meters   (power decreases by 1% for every additional 100 meters, up to 4000 meters)

    Cooling method

    forced ventilation

    Noise(dB)

    48~60

    55

    65

    80

    Box color

    Left front door   black, other ice gray (GY09)

    Input cable

    bottom/back

    Maintenance surface

    front/top/side

    front/back

    Dimensions

    Width

    (mm)

    350

    450

    600

    1000

    1200

    1400(6P)

    Deep

    (mm)

    700

    850

    800

    800

    900

    1000

    High

    (mm)

    900

    1230

    1400

    1680

    1850

    1900

    Weight(KG)

    177

    208

    215

    277

    290

    310

    350

    510

    570

    720

    820

    960

    1350

    1450

    1750

    1950

    2850

    Input device

    Terminal block

    Output device

    Terminal block

                                             

     

     

     