Battery LBT12-250 12V 250AH
12V 250Ah Rechargeable Sealed Lead Acid (SLA) Battery |Deep Cycle AGM
LBT Power High-Endurance Batteries are the perfect energyheartbeat for our UPS systems. Specifically engineered to complement ourDSP-controlled architecture, these batteries utilize advanced deep-cycletechnology to provide long-lasting backup power and exceptional dischargeperformance. Built with a rugged, flame-retardant casing and high-purity leadplates, they offer superior thermal stability and a prolonged service life evenunder frequent cycling. Designed for critical missions, they ensure that yourindustrial automation and medical infrastructure remain fully operational,bridging the gap between grid failure and seamless power restoration withabsolute certainty.
General Features:
• 10 years designlife
• Very lowSelf-discharge rate
• Wide range ofoperating temperature
• 100% Sealed andmaintenance free
• Goodconductivity
• Excellent chargeacceptance
• Safe andreliable explosion-proof regulating valve
Applications:
• Telecommunications
• UPS、Data Center
• EnergyStorage,Electric Systems
• EmergencyLighting,Security
• Medical,ElectronicEquipment
• Motive Power
Standards:
• Compliant withIEC60896, IEC61427, GB/T19638,YD/T1360-2015,YD/T799, DL/T637
• Certified forTLC, CE, RoHS and Reach compliance
• The companyAokly is certified under TS16949,OHSAS18001,SA8000, ISO9001, ISO14001,ISO45001and
ISO50001 management systems


Specifications
Nominal Voltage
12V
Nominal Capacity(C20)
250Ah(1.8V/cell@25℃)
Dimensions
520*267.5*220/225(mm)
Approx .Weight
67.0kg ±3%
Internal Resistance
Approx.2.6mΩ@25℃
Terminal
φ20*M8
Operating Temperature Range
Discharge:-20℃~55℃(-4~104°F)
Charge:0℃~40℃(-4~104°F)
Storage:-20℃~55℃(-4~122°F)
Nominal Operating Temperature
Range25±3℃(77±5°F)
Max.Charging Current
62.5A @25℃
Charging voltage(25℃)
Float:2 .25V~2.30V/cell
Temp.Coeffcient:-3mV1℃
Equalization:2.40V~2.45V/cell
Temp.Coeffcient:-4mV℃
Cycle:2.40V~2.45V/cell
Temp.Coeffcient:-5mV1℃
Effect of temperature to rated
Capacity(C10)40℃(104°F) 105%
25℃(77°F) 100%
0℃(32°F) 86%
Self Discharge
≤3%/month@25℃
Casing material
ABS(UL94 HB or V-0 optional)
Constant Current Discharge*(Amperes @25℃177 F)
Time
10min
15min
30min
1h
2h
3h
4h
5h
8h
10h
20h
9.60V
426
383
241
135
80.2
61.2
49.2
41.7
27.3
24.9
13.1
10.20V
412
365
233
129
76.5
58.4
46.9
39.8
26.0
23.7
12.8
10.50V
387
319
223
126
74.7
57.3
45.8
38.9
25.8
23.4
12.7
10.80V
358
297
210
121
72.8
56.1
44.7
34.8
25.1
22.9
12.5
11.10V
325
274
189
108
71.0
53.8
43.5
33.2
24.4
22.3
12.4
Constant Power Discharge*(Watts/Unit @25℃177°F)
Time
10min
15min
30min
1h
2h
3h
4h
5h
8h
10h
20h
9.60V
4658
3930
2611
1599
901
724
555
474
313
288
156
10.20V
4442
3712
2466
1511
859
684
529
452
298
274
149
10.50V
4053
3524
2360
1447
839
664
517
441
296
271
148
10.80V
3814
3306
2223
1372
818
650
505
395
288
265
145
11.10V
3574
2969
2000
1234
797
602
491
377
280
258
138